OSMOS Installation and Removal Instructions

Installation

Point the telescope at the zenith
Remove any filter wheel attached to the MIS
Raise OSMOS to MIS with OSU sticker facing North
Attach with 3/8-24 1-1/4" SHCS
Disconnect Cart Plunger [see photo below]
Lower OSMOS Cart
Remove OSMOS Cradle (9 bolts, 5mm Allen Wrench)
Install 4k and HE
Add weights to telescope

Removal

Remove weights from telescope
Point the telescope at the zenith
Remove the 4k and HE
Attach the OSMOS Cradle (9 bolts, 5mm Allen Wrench) [see photo below]
Retract the plunger on the cart
Raise OSMOS Cart with high side toward ribs [see photo below]
Check that OSMOS is seated in the Cart
Insert the Cart Plunger
Unbolt OSMOS from MIS
Lower OSMOS
Photos:
Cart Plunger retracted


Cart cradle attached to OSMOS


Correct orientation of Cart 


Return to: [ OSMOS Home Page | MDM Observatory [Mt Server] | MDM Observatory [OSU] ]